- Mechanical measurements: rotor’s axial shift and rotor’s differential expansion (axial growth), other displacements, measured by the sensor with DC-current output.
- Complies with requirements of technical conditions TU U 33.2-32436145-002:2008.
- Listed in the State Register of Measurement Instruments of Ukraine.
- Single or dual sensors connection.
- Provides supply voltage for sensors.
- Verification of measument veracity by comparison of two connected sensors signals.
- Individual sensor calibration capability.
- Indication in mm or μm.
- 2 NO relay outputs for signaling.
- Relay operation under ‘AND’/’OR’ condition.
- Interference and powerfailure faults protection.
- Programmable DC-current output 0..5, 0..20 or 4..20 mA.
- Interface RS-485, protocol Modbus (RTU).
- Five-digit green LED display with 20 mm symbol height.
Technical specifications
Measuring range, mm* |
0.5..10 |
Reduced measurement error, % |
±3 |
DC-current output error, mA |
±0.05 |
Supply voltage (depends on model) |
220VAC 50Hz |
Sensors supply voltage |
(15..28)VDC |
Least significant digit value |
0,01 mm or 1 μm |
Operating temperature range:
|
+5°С..+110°С |
Protection type (IP code):
|
|
Size (W×H×D), mm |
144×74×120 |
* — depends on sensor type.
Eddy current displacement transducer manufactured by Vicont, contactless inductive gap sensor manufactured by TURCK or their analogs can be used as the sensor.
Scope of supply:
- digital measuring device IP-5-TK–ХXХ:
ХXХ – supply voltage variants:
«24V» – 24 VDC;
no marking – 220 VAC 50Hz;
- remote console for device setting up;
- displacement transducer (option);
- AC/DC converter 220VAC/24VDC (if 24VDC supply voltage variant is choosed).
Ordering designation
Linear and angular shift meter IK-1-TK-5.
Specify IP-5-TK model, type and quantity of displacement transducers when ordering.
Example. Linear and angular shift meter IK-1-TK-5 composed of:
- digital measuring device IP-5-TK-24V;
- eddy current displacement transducer ВК-316ОС.01.