- Measurement and conversion of selsyn transmitter signals.
- Complies with requirements of TU U 33.2-32436145-002:2008.
- Listed in the State Register of Measurement Instruments of Ukraine.
- Rotation angle indication in deg.
- Rotation angle indication in custom scale units.
- Provides supply voltage for selsyn.
- Continuous selsyn fault detection.
- Can be connected with selsyn transmitter without the need of synchro receiver disconnection.
- 4 NO relay outputs for signaling.
- Programmable DC-current output 0..5, 0..20 or 4..20 mA.
- Interface RS-485, protocol Modbus (RTU).
- Five-digit green LED display with 20 mm symbol height.
Technical specifications
Rotation angle range, deg |
-3..354 |
Measurement error (without sensor error), deg |
±2.5 |
DC-current output error, mA |
±0.05 |
Supply voltage |
220VAC 50Hz |
Selsyn supply voltage |
(7.5..10)VAC 50Hz |
Least significant digit value |
0.1; 1 |
Operating temperature range |
+5°С..+50°С |
Protection type (IP code) |
IP41 |
Size (W×H×D), mm |
144×74×120 |
Scope of supply:
- digital measuring device IP-2-TK-XX:
XX – sensor supply variant:
«VP» – external power supply;
no marking – built-in power supply;
- remote console for device setting up;
- selsyn transmitter (option).
Ordering designation
Linear and angular shift meter IK-1-TK-2.
Specify IP-2-TK model and selsyn type when ordering.
Example. Linear and angular shift (displacement) meter IK-1-TK-2 composed of
- digital measuring device IP-2-TK;
- selsyn type БД-1404Б.